ReportEngineering

What rooftop solar pays a factory in 2026

A worked example of a 500 kWp rooftop solar system on a Surabaya factory at the 2026 I-3 tariff: savings, payback, 25-year cash flow and the five inputs that move the answer most.

Download report (PDF)Download data (CSV)
Illustration for What rooftop solar pays a factory in 2026

Key points

  • A 500 kWp roof in Surabaya produces about 700 MWh a year, worth about Rp 780 million at the I-3 tariff.
  • At Rp 11 million per kWp, simple payback is about 7.7 years and the 25-year IRR about 12%.
  • Installed cost and self-consumption move the answer more than anything else.

Every factory owner asks the same question about rooftop solar: how long until it pays for itself? This is a worked example with stated assumptions, so you can see which numbers matter and replace them with your own.

The example

A factory in Surabaya on PLN’s I-3 tariff (above 200 kVA, medium voltage) installs 500 kWp on its roof. Daytime load is high enough to use all the solar output on site, so nothing is exported.

AssumptionValueBasis
Specific yield, Surabaya1,400 kWh per kWp per yearSatu Energy yield estimate
Tariff avoidedRp 1,114.74 per kWhPLN I-3, third quarter of 2026
Installed costRp 11 million per kWpSatu Energy assumption for 2026 commercial rooftop
Operation and maintenance1% of capex a yearSatu Energy assumption
Degradation0.5% a yearTypical module warranty
Tariff escalationNoneTariffs frozen since 2017
Result
  • 700 MWhSolar output in year one
  • Rp 780 mElectricity cost avoided in year one
  • 7.7 yrsSimple payback, including O&M
  • ~12%Project IRR over 25 years, unlevered
Source: Satu Energy worked exampleDownload CSVSatu Energy

The cash flow

The system is cash-positive from year eightCumulative cash flow, Rp billion, 500 kWp in Surabaya
-10-505101511.5 Cumulative cash
0481216202425

Before tax and financing. No tariff increase assumed; any increase shortens payback.

Source: Satu Energy worked exampleDownload CSVSatu Energy
Show data
YearCumulative cash
0-5.5
1-4.8
2-4.1
3-3.3
4-2.6
5-1.9
6-1.2
7-0.5
80.2
90.9
101.6
112.3
123.0
133.6
144.3
155.0
165.7
176.3
187.0
197.6
208.3
218.9
229.6
2310.2
2410.9
2511.5

Over 25 years the roof returns about Rp 11.5 billion net of its Rp 5.5 billion cost, without any tariff increase.

What moves the answer

Change one input at a time and the payback moves like this:

Installed cost moves payback the mostSimple payback when one input changes, years
Cost Rp 13 m per kWp 9.3 yrs
I-4 tariff (Rp 996.74) 8.7 yrs
Jakarta yield (1,290 kWh/kWp) 8.5 yrs
Base case 7.7 yrs
Tariff +10% 7.0 yrs
Kupang yield (1,650 kWh/kWp) 6.5 yrs
Cost Rp 9 m per kWp 6.2 yrs
Source: Satu Energy worked exampleDownload CSVSatu Energy
Show data
Scenarioyrs
Cost Rp 13 m per kWp9.3
I-4 tariff (Rp 996.74)8.7
Jakarta yield (1,290 kWh/kWp)8.5
Base case7.7
Tariff +10%7.0
Kupang yield (1,650 kWh/kWp)6.5
Cost Rp 9 m per kWp6.2

Five lessons from the sensitivities:

  1. Price the system properly. A Rp 2 million per kWp difference in installed cost moves payback by about 1.5 years in either direction. Compare quotes on the same specification: module brand and tier, inverter, structure, cabling and monitoring.
  2. Self-consumption is everything. This example assumes all output is used on site. Since the 2024 rooftop rules, exported power earns no credit. A factory that runs one shift on weekdays only may use 70% or less of its solar, which lengthens payback in proportion.
  3. Location matters, but less than you think. Eastern Indonesia’s sun is stronger, but yield differences of 10–15% move payback by about a year.
  4. A tariff rise is the upside. The freeze since 2017 has a growing cost to the state budget. A 10% tariff increase cuts payback by almost nine months.
  5. Large users save less per kWh. I-4 customers pay about 11% less than I-3, so the same roof pays back about a year later.

Before you sign

  • Get the quota. Rooftop systems need a slot in PLN’s annual quota for your grid system. The 2026 quota is about 1,065 MW, and the ministry proposed adding 400 MW.
  • Check the roof. A structural assessment is cheaper than a leaking or overloaded roof. Plan for re-roofing if the sheets have less than 15 years of life left.
  • Measure your load. A month of interval data shows how much solar you can really use, and whether a small battery would raise self-consumption.
  • Insist on monitoring. Without it, a failed inverter or string can go unnoticed for months. A 5% output loss over the system’s life costs more than the monitoring.

Try it for your site

The quick estimate on our home page gives yield and savings for any city. For a firm number, send us your roof plan, load data and tariff, and we will run the hourly model.

Sources

  1. Metro TV, electricity tariffs as of 31 August 2026 (I-3 Rp 1,114.74 per kWh)
  2. Investor Trust, PLN tariffs for July–September 2026 unchanged
  3. The Jakarta Post, Indonesia seeks to boost rooftop solar quota by 400 MW, 23 January 2026
  4. IRENA, Renewable Power Generation Costs in 2024

Summaries and analysis by Satu Energy. Programme and plan figures are not operating capacity unless stated.

Download the full report

One energy, limitless solutions.

How can we help?

Send location, capacity and stage. We reply within one working day.

Contact us